AuroraPy

AuroraPy is a python implementation of Aurora communication protocol for Power-One Aurora inverters.

It implements a serial Client and a TCP Client for who wants to convert RS485 to Ethernet.

Pip installation

pip install aurorapy

Manual installation

git clone git@code.energievalsabbia.it:ccatterina/aurorapy.git
cd aurorapy
python setup.py install

Usage

TCP Client

from aurorapy.client import AuroraError, AuroraTCPClient

client = AuroraTCPClient(ip='192.168.1.34', port=502, address=10)
client.connect()
try:
    print("Inverter serial number: %s" % client.serial_number())
except AuroraError as e:
    print(str(e))
client.close()

Serial Client

from aurorapy.client import AuroraError, AuroraSerialClient

# AuroraSerialClient(address, port, baudrate=19200, parity='N',
#                    stop_bits=1, data_bits=8, timeout=5)
client = AuroraSerialClient(port='/dev/ttyUSB0', address=10)
client.connect()
try:
    print("Inverter serial number: %s" % client.serial_number())
except AuroraError as e:
    print(str(e))
client.close()

Documentation

Documentation is here

Available commands

The available commands are:

  • 50: State request
  • 52: P/N Reading
  • 53: Reset auto-exclusion
  • 58: Version Reading
  • 59: Measure request to the DSP
  • 63: Serial Number Reading
  • 65: Manufacturing Week and Year
  • 67: Flags or switch reading (Only for Aurora Central)
  • 68: Cumulated Float Energy Readings (Only for Aurora Central)
  • 70: Time/Date reading
  • 72: Firmware release reading
  • 76: Latest 10 seconds produced Joules
  • 78: Cumulated Energy readings (Only for Aurora grid-ties inverters)
  • 86: Last Four Alarms
  • 101: System Info reading (Only for Aurora Central)
  • 200: Junction Box - State Request
  • 201: Junction Box - Val Request

Missing commands:

  • 85: Baud rate setting on serial lines
  • 103: Junction Box monitoring status (Only for Aurora Central)
  • 105: System P/N Reading (Only for Aurora Central)
  • 107: System Serial Number Reading (Only for Aurora Central)